Features:
- Fully configurable for different types of batteries (voltage levels, capacity, protections levels and delays).
- Determination of a battery status:
- State of charge (SOC)
- Depth of discharge (DOD)
- State of health (SOH)
- Effective capacity
- Cell resistance
- Cell monitoring:
- Measuring every cell voltage
- Temperature control
- Current monitoring (bidirectional Hall-Effect sensor with supply voltage 5 volts)
- Battery protections:
- Overcurrent
- Undervoltage
- Overvoltage
- High temperature
- Low temperature
- Heater control
- Cooler control
- Cell balancing
- Interfaces:
- CAN (CANopen protocol to configure the system, interaction with an external equipment)
System controller configuring
The system can be configured via CAN bus using the ElectricDeviceMonitor software. A USB-CAN adapter is required to connect a PC to the controller.
Parameter | Value |
Supply voltage, V | 9÷30 |
Current consumption @12 V, mA (max) | 80 |
Relays count | 2 |
Discrete outputs count | 4 |
Switching voltage of relays, V (max) | 55 |
Switching current of relays, A (max) | 8 |
Current sensor type | Hall-Effect sensor, bidirectional, supply voltage 5 V (LEM series HASS, HTFS) |
CAN bus speed, kbps | 125, 250 (default), 500 |
Number of BMS Logic boards (max) | 20 |
Dimensions (length × width × height), mm | 90 × 70 × 32.1 |
Weight, g | 80±5 |
Operating conditions | |
Operating temperature range, °С | -40÷75 |
The degree of protection from external influences | IP00 |
BMS Main 2.x | BMS Main 1.x | |
Relays count | 4* | 2 |
Discrete inputs count | 4* | - |
Discrete outputs count | 4* | 4 |
CAN | CANopen, J1939, support of SMA’s inverters, support of forklifts by Hyster-Yale, Crown, Combilift, support of UPS | CANopen, J1939, support of SMA’s inverters |
RS-485 | Modbus RTU | - |
Ethernet | Web interface, Modbus TCP | - |
Additional modules | BMS Wi-Fi (Web interface; sending log files to a remote FTP server) | - |
Data logging | on an SD-card (full battery and BMS state) | - |
The algorithm for calculating the parameters of the battery | Enhanced | Standard |
Algorithms for controlling the charging process | + | - |
Work with other BMS devices | BMS Display, BMS Indication, BMS Crown | - |
* The assignment of the relays, discrete inputs and outputs is configurable.