BMS Main 3 / BMS Main 3X

Controller / Strings controller

Modular BMS controller for 24-2000V batteries

Depending on firmware, device can act as a battery controller (BMS Main 3) that interacts with measuring modules, or as a controller of parallel batteries (BMS Main 3X).

BMS Main 3 can control up to 40 measuring modules and manage a battery consisting of 720 cells.

BMS Main 3X controls up to 32 batteries connected in parallel, each of them is managed by the BMS Main 3.

BMS Main 3 / BMS Main 3X

image

  • 6 switches for contactors
  • 8 discrete inputs
  • 4 discrete outputs

image

  • SOC, DOD, SOH estimation
  • Cycles, energy counting

image

  • 3xCAN, RS-485, USB
  • Wi-Fi, LAN, GSM (over an extension modules)

image

  • SD-card logging

Links

Documentation for BMS Main 3

Documentation for BMS Main 3X

Firmware for BMS Main 3

Firmware for BMS Main 3X

Downloads

ElectricDeviceMonitor

Compatible controllers (for BMS Main 3X only): BMS Main 3

Compatible measuring modules (for BMS Main 3 only): BMS Logic 12S, BMS Logic 18S, BMS Logic 12, BMS Logic 18, BMS Logic 2R

Compatible displays (for BMS Main 3X only): BMS Display

Compatible displays (for BMS Main 3 only): BMS Display, BMS Indication

Compatible additional modules: BMS IMD, BMS Wi-Fi, BMS LANmodule, BMS GSM

ParameterValue
Supply voltage, V9 to 32
Current consumption @24 V, mA (max)150
KEYRUN or CHARGE_ON signal for powering on the device, V, (minimum)8.5
Number of BMS Logic devices (relevant for BMS Main 3)1 to 40
Number of cells (maximum) (relevant for BMS Main 3)720
Number of parallel batteries (relevant for BMS Main 3X)1 to 32
Number of programmable switches for contactors (9-32V, 2.5A)6
Number of programmable discrete inputs (dry contact)6
Number of programmable discrete inputs 9-32V2
Number of programmable discrete outputs (open drain, 40V, 1A)4
Number of connected current sensors (two signal lines for each sensor)3
Error in measuring signals from current sensors, V, max± 0.001
Current sensor typesHall-Effect sensor, bidirectional (LEM series: HASS, HTFS, DHAB or analogues)
Number of HV measurement inputs (two signal lines on each input)2
High voltage measurement range, V10 ÷ 1000
High voltage measurement error, V, max± 2
Number of connected external temperature sensors (100 kOhm NTC-thermistors)2
Temperature measurement error using external temperature sensors, ºC, max± 2
Temperature measurement error using a built-in temperature sensor, ºC, max± 2
Humidity measurement error using a built-in humidity sensor, %, max± 10
Current in the HVIL, mA, typical25
Total resistance in the HVIL, Ohm, max200
Number of USB interfaces1
USB speed, Mbit/s12
Number of CAN interfaces3
CAN speed, kbps125, 250 (default), 500, 1000
Number of RS-485 interfaces2
RS-485 bus speed, bps600, 1200, 2400, 4800, 9600 (by default), 19200, 38400, 57600, 115200
Output voltage of CAN2 power supply, V5 ± 0.5
Output current of CAN2 power supply, mA, max400
Rated insulation voltage, AC 50Hz, 1 minute, VRMS (minimum): 1) Between CAN1, RS-485-1, discrete inputs/outputs and power lines, 2) Between CAN1, RS-485-1, discrete inputs/outputs and HV measurement lines, 3) Between power lines and HV measurement lines3500
Dimensions (length × width × height), mm200 × 120 × 12
Weight, g150 ± 10
Operating temperature range, °C-40 ÷ 85
The degree of protection from external influencesIP00

BMS Main 3 / BMS Main 3X can be configured using the ElectricDeviceMonitor over USB, CAN or a TCP network (in this case, the BMS Wi-Fi or BMS LANmodule must be installed).